Technical Specifications
Power: The MVP detector operates across the 9V DC - 240V AC power
range.
Current Consumption: 19.2 mA @ 9 VDC 18.8 mA @ 12 VDC
17.3mA @ 24 VAC 9.5 mA @ 24 VDC
13.5 mA @ 115 VAC 11.0 mA @ 237 VAC
Temperature: -40F to + 180F
Environmental Protection: Circuit board is conformally coated
Enclosure: Extruded anodized aluminum,
Height = 3.25 inches 83 mm
Width = 2.56 inches 40 mm
Depth = 3.65 inches 90 mm
Output Relays: 1A/30V DC
Connector: 86CP11 compatible with 11pin Octal DIN rail mountable socket or
wire harness
Surge Protection: The detector is protected with neon discharge lamps, zenner diodes
and surge arrestors.
Loop Input: Transformer isotated
Grounded Loop: The loop isolation transformer allows operation with poor quality
loops.
Loop Inductance Range: 20 to 2000 microhenries with Q factor of 5 or higher.
Tuning: Detector automatically tunes to the loop after power application or
reset.
Tracking: Detector automatically tracks and compensates for environmental
changes
Power Indicator: Green LED solid light indicates power
Loop Failure Indicator: Green LED blinks indicates loop problem. DIP switch 4 set to fail
secure, Relay 2 may be used to act as loop failure output to control
board.
Loop Failure Memory: Green LED blinks with fast consecutive blinks indicates past loop
problem that healed.
Detect Indicator: Red LED solid light indicates detection
Extend Indicator: Red LED blinks after a car left the loop indicates time extend feature
Sensitivity: Set by ten position rotary switch
Frequency: Set by three position toggle switch
Infinite Presence Mode: DIP switch selectable presence
Limited 4 Minutes DIP switch selectable
Presence Time: DIP switch selectable
Second Presence Relay: DIP switch selectable
Pulse On Exit / Entry: DIP switch selectable
Fail Safe / Secure : DIP switch selectable
Filter: DIP switch selectable 2 seconds
Exteded Detection: DIP switch selectable 3, 6 and 9 seconds