Vista de página 11
10
RAMSET
www.ramsetinc.com
RAM 5000 • 5100 • 5200
Dip Switch “A Dip Switch “B Dip Switch “C”
“Intelligate” Control Board
DIP SWITCH CONFIGURATION
Figure 11
DIP SWITCH “A”
DIP SWITCH “B”
Dip Switch “A” 4 - 1/2 HP ERD
Dip switch A4 works with Dip switch B8
DIP A4 B8 Sensitivity
OFF OFF Most Sensitive
ON OFF 1/2 Hp — Medium Sensitivity
OFF ON 3/4 Hp — Medium Sensitivity
ON ON Least Sensitive
Dip Switch “B” 8 - 3/4 HP ERD
Dip switch B8 works with Dip switch A4
DIP A4 B8 Sensitivity
OFF OFF Most Sensitive
ON OFF 1/2 Hp — Medium Sensitivity
OFF ON 3/4 Hp — Medium Sensitivity
ON ON Least Sensitive
Dip Switch “B” 2; “PRE WARN”
Used with JP2 “Relay Connections”: pins 7 & 8.
Triggers a relay, for an alarm or light (not included), for 3 sec-
onds before the gate will move in any direction.
Sw. Function:
ON Triggers the relay on JP2 pins 7 & 8 for 3 seconds.
OFF Regular working conditions
Dip Switch “B” 3; “CONSTANT WARN”
Used with JP2 “Relay Connections”: pins 7 & 8.
Triggers a relay, for an alarm or light (not included), to be ac-
tive anytime the gate is in motion.
Sw. Function:
ON
Triggers the relay on JP2 pins 7 & 8 while the gate
is moving
OFF Regular working conditions
Dip Switch “B” 1; Not in use at this time.
Leave in the ‘Off’ position.
Dip Switch “B” 4,5,6 & 7; Not in use at this time.
Leave in the ‘Off’ position.
Dip Switch “A” 1, 2 & 3;
AUTOMATIC TIMER TO CLOSE GATE
‘0’ is “OFF” ‘1’ is “ON”
Switch 1 2 3 Gate Open Duration:
1 1 1 60 seconds
1 1 0 45 seconds
1 0 1 30 seconds
1 0 0 15 seconds
0 1 1 10 seconds
0 1 0 05 seconds
0 0 1 00 seconds
0 0 0 Disabled - command required to close