Controlled-products-systems-group 790919 Manual do Utilizador Página 9

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 8
Page 9
November, 2003
455 D Control Panel Installation Instructions
ADVANCED PROGRAMMING
+
Display Function Default
MAXIMUM TORQUE AT INITIAL THRUST:
The motors operate at maximum
torque (ignoring the torque setting)
at start of movement. Useful for
heavy leaves.
4 = Enable
No = Disabled
LAST STROKE AT CLOSING:
The motors are activated at full
speed for 1s to facilitate locking of
the electric lock.
4 = Enable
No = Disabled
REVERSING STROKE:
Before opening, while the gate is
closed, the motors thrust to close
for 2 s thus facilitating release of the
electric lock.
4 = Enable
No = Disabled
LEAF 2 OPENING DELAY (2S):
Enables delayed start (at opening) of
leaf 2, avoiding interference between
leaves.
4 = Enable
No = Disabled
FAIL SAFE:
If this function is activated, it
enables a function test of the
photocells before any gate
movement. If the test fails
(photocells not serviceable), the gate
does not start the movement.
4 = Enable
No = Disabled
PRE FLASHING (5S):
Activates the flashing lamp for 5s
before start of movement.
4 = Enable
No = Disabled
ELECTRIC LOCK ON LEAF 2:
For using the electric lock on leaf 2
instead of on leaf 1.
4 = Enable
No = Disabled
F
+
Display
Function Default
INDICATOR-LICHT:
If 0 is selected, the output functions
as a standard indicator-light (lighted
at opening and pause, flashing at
closing, and off when gate closed).
Different figures correspond to timed
activation of the output, which can be
used (via a relay) to power a courtesy
lamp. Time can be adjusted from 0
to 59s in 1s increments, and from 1.0
to 4.1 min. in 10s steps.
0 = Standard Indicator-Light
From 1 to 4.1 = Timed Output
CLOSING PHOTOCELLS REVERSE AT
RELEASE:
Enable this function if you want the
closing photocells to stop the gate
movement and reverse it after the
beam is cleared. Default setting is
immediate reverse.
4 = Enable
No = Disabled
A.D.M.A.P. FUNCTION:
If this function is enabled, the safety
devices operate in compliance with
French standard NFP 25/362.
4 = Enable
No = Disabled
ASSISTANCE REQUEST (COMBINED WITH
NEXT FUNCTION):
If activated, at the end of countdown
(settable with the next function, i.e.
“Cycle programming”) it effects 8s of
pre-flashing at every Open pulse (job
request). Can be useful for setting
scheduled maintenance jobs.
4 = Enable
No = Disabled
CYCLE PROGRAMMING:
For setting count down of system
operation cycles. Settable (in
thousands) from 0 to 99 thousand
cycles. The displayed value is
updated as cycles proceed. This
function can be used to check use of
the board or to exploit the
“Assistance Request” function.
EXIT PROGRAMMING:
Exit from programming and return to
display of inputs status.
Vista de página 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Comentários a estes Manuais